Category: Telecommunication

  • GL.iNet GL X3000: Lower the fan start temperature via SSH

    On the GL X3000, the Web UI only allows setting the fan start temperature as low as 70°C. At first glance that feels a bit high, but it is probably fine.

    Are you sure gif

    The AP MT7981B is specified for an operating temperature range of -40°C to 125°C, so 70°C is well within spec (1). Still, I wanted the fan to kick in earlier because I am dealing with unwanted random restarts and I wanted to reduce heat as a possible factor. Mine was idling at around 65°C, so waiting until 70°C meant the fan would barely ever run. And honestly, I would rather have a bit more airflow than trust that every single component inside the box is equally happy at those temps.

    Here is how to change the fan activation threshold over SSH.

    Step 1: Connect via SSH

    Step 2: Edit the fan config

    Open the fan config file

    vi /etc/config/glfan

    You should see something like this

    config globals 'globals'
        option enabled '1'
        option sysfs '/sys/devices/virtual/thermal/thermal_zone0/temp'
        option warn_temperature '75'
        option div '1000'
        option temperature '50'
    Code language: JavaScript (javascript)

    The setting that controls when the fan starts is option temperature . Change it to the temperature where you want the fan to kick in. Save and exit.

    Step 3: Restart the fan service

    /etc/init.d/gl_fan restart

    Done. The fan should now start at your new threshold.

    Reference

    1. AP Datasheet: https://one.openwrt.org/hardware/MT7981B_Wi-Fi6_Platform_Datasheet_Open_V1.0.pdf
  • GL.iNet GL-X3000 router using a microSD Card as swap

    GL.iNet GL-X3000 router using a microSD Card as swap

    If you’re running AdGuard Home or other memory-hungry services on a device like the GL.iNet GL-X3000, you’ve probably hit the dreaded Out of Memory (OOM) errors, especially when using large blocklists like HaGeZi Pro++ or OISD.

    Here’s how I gave my router a massive stability boost by converting a 7.5 GB microSD card into a full dedicated swap partition.

    (more…)
  • Auerswald COMpact 5020 VoIP von ISDN auf VoIP umstellen

    Heute habe ich eine Auerswald COMpact 5020 VoIP von einem ISDN Anschluss mit 2 Nutzkanälen auf VoIP mit 8 Kanälen umgestellt. Die Umstellung verlief, nicht zuletzt dank dem Auerswald Support, nach anfänglichen Problemen relativ gut.

    (more…)
  • SoundStation IP 5000 mit einer FritzBox verbinden

    Die Einstellungen der SoundStation IP 5000 sind meines Erachtens nach viel zu kompliziert und wenn man das erste mal davor sitzt kann es gut passieren, dass man nur Fragezeichen über dem Kopf hat. Hinzu kommt die unglaublich langsame Geschwindigkeit, vor allem beim Neustarten..

    (more…)
  • SoundStation IP 5000 webinterface login

    Wenn man bei einer SoundStation IP 5000 auf das Webinterface zugreifen möchte (valide IP-Konfiguration vorausgesetzt), wird man vom Webbrowser zur Eingabe von Benutzername und Passwort aufgefordert. Diese sind selbstverständlich nirgendswo Dokumentiert oder niedergeschrieben.

    (more…)